Brand Name : BAIKONG
Certification : IEC,GB
Place of Origin : Sichuan,China
MOQ : 1set(MOQ)
Price : $1000-$100000/set
Payment Terms : L/C, Western Union, T/T
Supply Ability : 300 sets/sets per week
Delivery Time : 15Days OR To be negotiated
Packaging Details : Standard wooden boxes for outer packing/To be negotiated
Product Name : 15/17 Outdoors High Pressure Stationary Type Ring Network Cabinet
Color : Green,Red,Blue,Non-standard Custom
Size : customizable
Series : Ring Network Cabinet
Structure Form : Desktop
Application : Industrial And Mining, Residential District High-Rise Buildings, Schools, Etc
Rated Working Voltage : 3-12kV
Rated Bus Current : 630A
IP Grade : IP30-65/Customizable
QA : 1year
15/17 Outdoors High Pressure Stationary Type Ring Network Cabinet
Product overview
Overview fixed AC metal closed switchgear (ring network cabinet) is a rated voltage of 12kv.The AC high voltage electrical device with a rated frequency of 50Hz is mainly used for three-phase AC ring network, terminal distribution network and industrial electrical equipment, playing the acceptance and distribution of electricity and other functions, which is also suitable for equipment with out-in-box substation.
Main technical parameters
| No. | Name | Unit | FN12-10 | FZN25-12 | |
| 1 | Fuses are rated for the current current | A | 100 | ||
| 2 | Rated transfer current | A | 1500 | 2000 | |
| 3 | Composite apparatus | Rated short-circuit-off current | kA | 1500 Ground and alternate 75; isolation break 85 | |
| 4 | 31. 5 | ||||
| 5 | mechanical life | 次 | 2000 | 1000 | |
| 6 | Auxiliary circuit is 1min | kV | 2 | ||
| 7 | Operating voltage of the electric operating mechanism | V | AC / DC 220; 110 | ||
| 8 | Levels of protection | IP2X | |||
| 9 | Outline size (wide x deep x high) | mm | 650 (850) X900X2000 (2200) | ||
Main technical parameters of the vacuum circuit breaker
| No. | Name | Unit | FN12-10 | FZN25-12 | |
| 1 | R+ated voltage | N | 12 | ||
| 2 | The 1min working frequency withstand voltage | N V  | 
			Ground to ground 42; isolation break 48 | ||
| 3 | Lightning impact voltage (peak) | kV | Ground to ground and alternate 75; isolation break 85 | ||
| 4 | Rated frequency | Hz | 50 | ||
| 5 | Main bus rated current | A | 630 | ||
| 6 | Load switch | rated current | A | 630 | |
| 7 | Power life at the rated current | KVA | No less than 100 | ||
| 8 | Disconnect the no-load transformer capacity | KA/S | 1250 | ||
| 9 | Rated heat-stable current | KA | 20/4;earth switch 20/2 | ||
| 1 0  | 
			Rated stable current (peak) | KA | 50 | ||
| 1 1  | 
			Rated short-circuit turn-off current (peak) | 次 | 50 | ||